Select
The Spec Of Calibration : Robust aluminum alloy scale plate.
Two lengths arm with flexibility to fixed working surface.
Select
The Spec Of Calibration : 1. Digital type with large LCD, easy to read.
2. With zero setting installation, can be makes comparing mensuration.
3. Metric/inch interchange switch, convenient to use both of metric & inch size.
4. A PC box included. 1. Measuring range: 150/200/300mm. 2. Minimum reading: 0.01mm. 3. Tolerance: +-0.03mm. 4.....
Select
The Spec Of Calibration : Applications: Temperature sensors, thermocouple wire and metal-sheathed, mineral insulated cable for temperature sensing applications in plastics manufacturing, chemical processing, packaging, HVAC, heat treating, food processing, primary metals, bio-medical, aerospace, and more. 1.J Tpye:-200 oC ~1000oC2....
Select
The Spec Of Calibration : •PP-6750V is an intelligent time recording terminals designed to meet variant applications in time attendance and access control, lift control & ARM/DISARM security requirements. Each terminal can be operated independent simply or through PC/Internet adapter PC-T100 to fulfill the multiple doors access system. Th....
Select
The Spec Of Calibration : 1. A very reliable and precise counting machine for all shapes and sizes of tablet & capsule.
2. Simple to set up and operate, compact and easy to clean.
3. Very smooth feeding and gentle scrolling of products.
4. Stabilzed light beam and photocell system are not affected by voltage fluctuating or ambient ligh....
Select
The Spec Of Calibration : Product Name:Tension Sensor / Load Cell Fit for tension controller HS-808 and HS 802. ....
Select
The Spec Of Calibration : This state-of-the-art, gel-filled low maintenance pH-electrode with excellent pressure resistance is specifically developed for reliable measurements in bioprocess. With pressure resistance to 6 bar and silver-ion trap to prevent fouling of diaphragm in sulfide-bearing media, the glass body pH electrode can be used on....
Select
The Spec Of Calibration : 1. Competitive prices, small order acceptable.
2. Sales method: export, manufacture.
3. Payment term: T/T. 1. CD-KR: 1-9990PPM. 2. CD-PH600: 0-14PH. 3. CD-TWN: 0-2999PPM. 4. CD-GB: 10PPM and up green / red. ....
Select
The Spec Of Calibration : * Features :
Commonly used for tightening head bolts and other bolts where a torque angle is required. ▲ TAG-342A : Use with 1/2" DR.▲ QA-1504 : Use with 3/4" DR. ....
Select
The Spec Of Calibration : TWIN CALIBRATION MACHINE - PWT460
Founded in 1985 has morn than 27 years of experience, PIN YING is a leading provider in developping and manufacturing of plastic extruder included downstream machinery for profiles and pipes. And today, we are striving harder that for service of customers’demands. During long time e....
Select
The Spec Of Calibration : 1. The vernier caliper is a precision tool that can be used to measure internal and external distances quite accurately. To learn more about digital vernier caliper, please take a close look at this website, and feel free to contact E-Base for more information.
2. 2 items: SV-02-150, SV-02-200. 1. Dimension(mm): 4....
Select
The Spec Of Calibration : This SWR&WATT meter is a highly accurate RF meter for measuring Forward Power, Reversed Power,and VSWR by using cross-needle analog meter.
Select
The Spec Of Calibration : Material of case, cover, and part of connection. 1. Material of sensitive stem: SUS304(#316 also available). 2. Dial scale plate: Alumimum-white background with black figures & marks. 3. Temperaure range: -50~+600oC. 4. Outside dia. of stem: Normal 6.3mm, Max. 4~12mm by orders. 5. Length of stem: 2"~25&quo....
Select
The Spec Of Calibration : Accessories:
1. Body.
2. Loading plates x 4.
3. TC bolt bushing.
4. Hex bolt bushing.
5. Metal case. 1. Capacity: 126000 lbs & 500 KN .
2. Measurement unit: 10 KN(option: 5KN).
3. Bolt size: M16, M 20, M22, M24,M27(1-1/4").
4. Accuracy: 2%.
5. Weight: 9.6 kg. ....
Select
The Spec Of Calibration : 1. SMT application.
2. Display: 1999 counts. digit is 11mm high.
3. DC voltage: 600V1.0%.
4. AC voltage: 600V1.5%.
5. AC current: 2A/20A/200A2.0%.
6. Max. diameter for conductor: O 28mm. 1. Resistance: 2K+1.0%.2. Data hold. ....
Select
The Spec Of Calibration : Made by special and durable plasitc, and easy to operate. Ideal gauge to measure the offset of the wheel up to 23". ....
Select
The Spec Of Calibration : 1. 3 1/2 digits LCD with a max readingof 1999.
2. Low battery indication.
3. Overload protection.
4. Accessories: test lead, battery (6F22 (9V) x 1), instruction manual. 1. DCV: 200m-2000m-20-200-1000V. 2. ACV: 200~750V. 3. Size/ weight: 128 x 70 x 28 mm/ 137 g. ....
Select
The Spec Of Calibration : 1. Directly lock-in modular stack valves device.
2. Excmpted from pressure gauge piping.
3. Sealing of pure oil lessen pulsation effect. Please refer to the attached file. ....
Select
The Spec Of Calibration : 1. Product name: normal pressure gauge.
2. built in with flangs.
Select
The Spec Of Calibration : ASTM D1148
This chamber provides a high UV tube with a wavelength 253mm to test a material's charactor after expose to the light. 1. Timer: 0~999 hours. 2. Light source: 15W UV tube x 2. 3. Inner dimension: 50 x 30 x 30cm. ....
Select
The Spec Of Calibration : ・ Blinking Alarm Mechanism: Using On Screen Display (OSD) function to create the blinking signal when event occurs, the location, size and blink timing of the blinking signal can be configured to match the motion detection setting in DVR. When event occurs, the event signal can seamlessly trigger the alert mechanism ....
Select
The Spec Of Calibration : * 1/8" NPT botto, connection, 2-3/4" ( 70mm ) O.D.
* Blue compound oil fillec, kg/cm2 & psi 1. Press.Scale:-30-0-2502. psiRefrigerants:R22, 134a, 404 ....
Select
The Spec Of Calibration : Our parts, tools and services are dedicated to helping customers to optimize the performance of their processes. 1. 36"/60"/72".2. R134a aluminum.3. Manifold gauge set.4. 3 charging hoses.5. 1 pair of quick couplers. ....
Select
The Spec Of Calibration : 1. High efficiency high precision counter and packer.
2. Alarm of signal and buzzor will be on when shortage of materials, bag not properly opened, sealed or jammed etc. and machine will be off automatically.
3. Print Unit and optic fiber sensors.
4. Open sewing line.
5. Finish pack conveyor.
6. Bags total coun....
Select
The Spec Of Calibration : G2:1.5”Pressure gauge - 10 Kgs
G2-1: 1.5”Pressure gauge – 10 Kgs Pressure Type:G2:Air type are availableG2-1:Hydraulic type are available ....
Select
The Spec Of Calibration : 1. Description:
2. Ranges: 30m/60m twin photoelectric beam sensor.
3. Character:
(1)A.G.C. circuit.
(2)high grade aspheric lens.
(3)frost & dew protection.
(4)adjustable beam interruption period.
(5)rain, dust & insect protection.
(6)easy optical alignment, and extra fine adjustment facility. 1. Twin beam.
....
Select
The Spec Of Calibration : 1. Cuts perfect 90 degree miters in a single setting.
2. Die-cast aluminum.
3. The gauge fits any design with a basic 3/4" (width) x 3/8" (depth) dimension slot.
4. Because it is adjustable by steel balls, it runs exactly and smoothly on the slot. This double faced miter gauge ensures 90 degree miters....
Select
The Spec Of Calibration : 1. Temperature measuring range: -40.0℃~ +120.0℃.
2. Accuracy of temp. measurement under normal temp.: ±0.2℃~ +30℃±0.5℃ at others.
3. Resolution: 0.1.
4. External sensor: PT1000.
5. Humidity measuring range: 0~95%RH.
6. Accuracy: ±0.1.
7. Recording cycle: normal mode 2 seconds~24 hours continuous set.....
Select
The Spec Of Calibration : • Use two hell-effect sensors
• For use with any multimeter with 200mv or/and 2v ranges for direct readout.
Input impedance of at least 1mΩ.
• An LED lights up when the clamp is under power
• Zero adjuslment knob to compensate the hysteresis effect DC measurements
• Safety:IEC 1010-1. IEC1010-2-032
....
Select
The Spec Of Calibration : - Accuracy: 0.5% / auto-zero function
- Overload fuse protection
- Compact form factor, with a bracket
- Volume: 143 (L) × 74 (W) × 39 (H) mm - Display: 3 1/2 digital with 0.86"(22mm) LCD- Range: 0.1pF~20mF (20000uF)- Stalls and accuracy:200P ± (0.5% rdg +1 dgt +0.5 pF)2000P/20n/200n/2u/20u/200u &p....