Select
The Spec Of Thermometers : 1. RF transmission.
2. Remote monitoring temperature change.
3. Dual display of temperature from two positions.
4. Auto refresh data.
5. Alarm mode for HI or LO temperature set.
6. Auto data logger.
7. Max and min temperature memory with time indication.
8. 24 hours clock indication.
9. Indoor and outdo....
Select
The Spec Of Thermometers : Electric contact thermometers for bottom mounted capillaries connection (mechanism & circuit structure of electric contactor):
1. Thermometers with contactor have made possible the automation of temperature control and increased the safety of energy consuming.
2. Electric contact acts as a switch control that follow....
Select
The Spec Of Thermometers : Product name: 8709 thermometer. Temp. range: -20°c to 50°c ( +14°F ~ 122°F ). ....
Select
The Spec Of Thermometers : Laser infrared thermometer model 58034, gun type, easy to use. The essential tools for repairing car A/C system and HVAC. Laser infrared thermometer model 58034, gun type, testing temperature with distance from -60 degree C to 550 degree C. ....
Select
The Spec Of Thermometers : The sensor bulb of thermometer filled with non-corrosive material liquid, and is widely use in industry as temperature control instruments. Includes: back connection (AL model),
bottom connection (AS model). 1. Diameter length: 4.5".
2. Connection: 1/2" PT.
3. Temperautre range: -50 ~ +200 C.
4. Accu....
Select
The Spec Of Thermometers : 1. Input: K, J, E, T, R.
2. Temperature measuring range: -200 ~ 1200°C, (-328 ~ 2501 fahrenheit degrees).
3. Accuracy:
(1) +/-0.1% rdg + 0.2 centigrade degrees between -200 ~ +200°F.
(2) +/-0.2% rdg + 1 centigrade degree above + 200 centigrade degrees.
4. Display: 4 digital LCD.
5. Data output: built-in RS-232....
Select
The Spec Of Thermometers : A baby's bath temperature is recommended to keep at around 40 degree Celsius. The bath thermometer can float on the water's surface, enables Parents to know whether the baby's bath water is in the ideal temperature range. 1. Lovely shape and available in bright color combinations to make attract baby's attention.
....
Select
The Spec Of Thermometers : 1. DE-3003: single channel DE-3004: two channels.
2. Data hold function.
3. Resolution:
(1) DE-3003: 0.1°C/ 0.1°F, 1°C/ 1°F.
(2) DE-3004: 1°C/ 1°F.
4. Wide measuring range: -50°C—i 300°C (.58°F~1999°F).
5. Low battery indication.
6. Celsius (°C) or fahrenheit (°F) for selection.
7. Offset adjustme....
Select
The Spec Of Thermometers : 1. Type: thermocouple K, J, E, T.
2. Auto range.
3. Resolution: O1°C/°F or l °C/°F.
4. Single channel-DE-3005/DE-3005A/DE-3005B.
5. Dual channel-DE-3006/DE-3006A/DE-3006B.
6. Simultaneous max/min hold.
7. Data hold.
8. °C/°F units select.
9. Relative measurement.
10. Sampling rate: approx. 2 times/sec.
Select
The Spec Of Thermometers : 1. Water proof.
2. High accuracy.
3. Resolution 0.1°C.
4. Temp.Range: -30°C~70°C. 1. Sampling rate: lOsec./time. 2. Waterproof level: IP-65. 3. Over range display"_ _._"display. 4. Battery life: approx. 2 years. ....
Select
The Spec Of Thermometers : 1. Maximum! minimum data hold.
2. Resolution: 0.1°C.
3. Low cost.
4. Measurement temp. range: -50°C—I 00°C(DE-20W) ; -10°C—70°C(DE-20).
5. Accuracy : -50°C-40°C ± 1.8°C ; >40°C-100°C ± 3.0°C.
6. Sampling rate: every 10 seconds.
7. Over range indication: “Hi” or “Lo” display (DE-20W).
....
Select
The Spec Of Thermometers : 1. Auto range.
2. Type K, J, E, T, R, S thermocouple thermometer.
3. Fast response.
4. High accuracy.
5. Auto power off selection.
6. Resolution 0.1 °C/°F or 1°C/°F.
7. Simultaneous max/min/avg reading memory.
8. Max hold, min hold, data hold.
9. Relative measurement.
10. Manual operate 10 sets of built-in....
Select
The Spec Of Thermometers : Application: refrigeration tool. pen digital thermometer -50 to 200C. ....
Select
The Spec Of Thermometers : 1. Includes: back connection (BL model), bottom connection (BS model), adjustable every angle type (BA model).
2. Material: all stainless steel. 1. Diameter : 1", 1.5", 2", 2.5", 3", 4", 5", 6'.
2. Temperature range: -50 ~ +600 C.
3. Sensor bulb diameter: standard 6.3 mm.
4.....
Select
The Spec Of Thermometers : 1. Product name: bi meta thermometers .
2. All stainless steel material, can make various size and specification as customer's request by ordered. 1. Diameter : 1" ~ 6".
2. Range : -50 ~ +600 C.
3. Accuracy : +/- 1%, +/- 1.5%.
4. Can accept to make any specification by ordered. ....
Select
The Spec Of Thermometers : Electric contact thermometers for bottom mounted capillaries connection (mechanism & circuit structure of electric contactor):
1. Thermometers with contactor have made possible the automation of temperature control and increased the safety of energy consuming.
2. Electric contact acts as a switch control that follow....
Select
The Spec Of Thermometers : Electric contact thermometers for bottom mounted capillaries connection (mechanism & circuit structure of electric contactor):
1. Thermometers with contactor have made possible the automation of temperature control and increased the safety of energy consuming.
2. Electric contact acts as a switch control that follow....
Select
The Spec Of Thermometers : Electric contact thermometers for back mounted capillaries connection (mechanism & circuit structure of electric contactor):
1. Thermometers with contactor have made possible the automation of temperature control and increased the safety of energy consuming.
2. Electric contact acts as a switch control that follows ....
Select
The Spec Of Thermometers : Electric contact thermometers for back mounted capillaries connection (mechanism & circuit structure of electric contactor):
1. Thermometers with contactor have made possible the automation of temperature control and increased the safety of energy consuming.
2. Electric contact acts as a switch control that follows ....
Select
The Spec Of Thermometers : Electric contact thermometers for back mounted capillaries connection (mechanism & circuit structure of electric contactor):
1. Thermometers with contactor have made possible the automation of temperature control and increased the safety of energy consuming.
2. Electric contact acts as a switch control that follows ....